Refer to the exhibit.
Switch2#
01:25:08: %PM-4-ERR_DISABLE: channel-misconfig error detected on Fa0/23, putting Fa0/23 in err-disable
state
01:25:08: %PM-4-ERR_DISABLE: channel-misconfig error detected on Fa0/24, putting Fa0/24 in err-disable
state
Switch2#
Switch1# show etherchannel summary
!output omitted
Group Port-channel Protocol Ports
--------------------------------------------
1 Po2(SD) LACP Fa1/0/23(D)
Switch2# show etherchannel summary
!output omitted
Group Port-channel Protocol Ports
--------------------------------------------------------
1 Po1 (SD) - Fa0/23(D) Fa0/24(D)